Pvc/Pvc/Swa/Pvc Overall Screened Instrument Cable Bs 5308 Part 2 : Type 2 300/500vrolliflex

Polyvinyl Chloride Insulated Polyvinyl Chloride Bedding Steel Wire Armoured Polyvinyl Chloride Sheathed Overall Screened Instrument Cable

Description

Single pair and multi-pair cables with copper conductor, PVC insulated, overall screened, PVC bedding, Steel wire armoured and PVC sheathed. Voltage rated at 300/500V

Construction

  • Conductor

    Plain annealed/tinned circular stranded copper conductor, conform to BS 6360 / IS:8130

  • Insulation

    PVC (Polyvinyl Chloride) / PE

  • Pairing

    Two insulated cores shall be uniformly twisted together to form a pair with maximum lay length of 100 mm.

    Note : Two pair cables with overall screen shall have four cores laid in quad formation.

  • Pair identification

    Colour code as per Appendix B or as per customer specification

  • Cabling

    Twisted pairs are laid up together, if necessary filled with nonhygroscopic material compatible with the insulation

  • Overall Screening

    Accumulated pairs screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.

  • Bedding

    PVC (Polyvinyl Chloride).

  • Armouring

    Galvanized steel round wire over the bedding.

  • Sheath

    PVC (Polyvinyl Chloride).

Pvc/Pvc/Swa/Pvc Individual & Overall Screened Instrument Cable Bs 5308 Part 2 : Type 2 300/500vrolliflex

Polyvinyl Chloride Insulated Polyvinyl Chloride Bedding Steel Wire Armoured Polyvinyl Chloride Sheathed Individual & Overall Screened Instrument Cable

Description

Multi-pair cables with copper conductor, PVC insulated, individual & overall screened, PVC bedding, Steel wire armoured and PVC sheathed. Voltage rated at 300/500V

Construction

  • Conductor

    Plain annealed/tinned circular stranded copper conductor, conform to BS 6360 / IS:8130

  • Insulation

    PVC (Polyvinyl Chloride) / PE

  • Pairing

    Two insulated cores shall be uniformly twisted together to form a pair with maximum lay length of 100 mm.

  • Pair identification

    Colour code as per Appendix B or as per customer specification

  • Individual Screening

    Each pair screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.

  • Cabling

    Twisted pairs are laid up together, if necessary filled with nonhygroscopic material compatible with the insulation

  • Overall Screening

    Accumulated pairs screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.

  • Bedding

    PVC (Polyvinyl Chloride).

  • Armouring

    Galvanized steel round wire over the bedding.

  • Sheath

    PVC (Polyvinyl Chloride).